G6A/390 - Watch Chronograph Mark II

Tests

Period 6 hours with the chronograph in action, 18 hours chronograph out of action 
Position Dial vertical / pendant up and dial horizontal / face uppermost
Temperature 15 degrees C.
Permissable errors irrespective of whether the chronograph movement is in or out of action 10 minutes - 1 second
1 hour - 5 seconds
6 hours - 20 seconds
24 hours - 60 seconds

Additional tests at -20 degrees C. and + 50 degrees C. for 3 hours with the chronograph in action followed by 3 hours with the chronograph out of action. Permissable errors as above.