G6B/159 - Watches Wrist Mk. VIIA
Tests
Period
12 hours in each position and temperature and 4 hours at 0C
Position
Dial up and pendant down
Temperature
0C and normal
Permissable errors
3 hours - 4 seconds
6 hours - 5 seconds
12 hours - 8 seconds
24 hours - 15 seconds